The sensor’s integral cable is permanently mounted, preventing contaminants from getting into the connector,while eliminating concern about the connector backing off the sensor. The connection integrity is critical for inaccessible sensor locations, says the vendor, such as inside gearboxes, or for underwater applications such as vibration monitoring inside tanks or on submersible pumps. Specifications are as follows: Sensitivity: 100mV/g. Acceleration range: 80g peak. Amplitude non-linearity: 1%. Frequency response: 1.0 - 5,000Hz (±10%) and 0.7 - 10,000Hz (±3 dB). Cable length: 16 to 100 feet standard J9T2A cable, steel overbraid or armored cable optional. Temperature range: minus 50º to +120º C. Height: 1.23 inches with cable exiting the side.
Wilcoxon Research Inc.
www.wilcoxon.com
800.WILCOXON