The new system with UL and CE marked components consists of the PDC (Profidrive Control) servo drive in conjunction with a flexible range of motors and connecting cables from product partners.
Simple connectivity to Simatic programmable logic controllers (PLCs) helps significantly reduce the engineering workload, while integration intoSiemens automation technologyvia its TIA Portal makes for simple commissioning and servicing. Attributes such as smart encoders and one-button tuning add to its plug-and-play startup. Communication takes place over Profinet using ProfisafeandProfidrive profiles. The new Safety Integrated function SLT (Safely Limited Torque) limits torque by monitoring motor current in running operation.
The Simatic Micro-Drive will offer units from 100 w to 1 kw and allow side-by-side rail mounting. The Micro-Drive PDC is available in a standard (only hardwired Safe Torque Off (STO)) and fail-safe version. STO, SS1, SLT, SLS, and SSM Safety Integrated functions are included with the Micro-Drive F variant. TIA Portal can be used to activate the safety functions with a Fail-safe PLC via PROFIsafe. Operating data can be transmitted directly to the controller from the Micro-Drive and transferred to Cloud-based platforms such as MindSphere over MindConnect.