Pressure Controls

Clippard’s Cordis HP500 pressure controls use a microcontroller, integrated pressure sensor, and two Clippard EV electronic valves. Pressure ranges of 0 to 500 psig are available.

This content was submitted directly to this website by the supplier.

Clippard Cordis Chp Pressure Controls

The inlet valve is connected to the moderately regulated supply pressure and the exhaust valve is connected to a port that vents excess pressure to atmosphere. Once a command is increased, the inlet valve opens up to allow supply pressure to pass over the sensor element which provides an active feedback for the micro-controller to satisfy the set point in the process. If at any point the sensor detects a value higher than the set point, the exhaust valve will modulate open to vent off the excess pressure to maintain a stable and accurate control pressure in the process.

Clippard’s Cordis HP500 pressure controlsare adaptable to a variety of sensors that can close the loop around pressure.

Features include:

• Smooth linear control

• Integrated internal or external sensor feedback

• Customizable pressure ranges and mounting options

• Proudly made in the USA.ISO 9001

Clickherefor further information.